- // FPGA reset control
- //
- // Interface with and control of the internal FPGA reset logic.
- //
- // Altera Cyclone IV E Remote Update block (cycloneiv_rublock):
- //
- // This block is a primitive, but there doesn't seem to be any
- // matching megafunction, except for the remote upgrade IP which
- // uses the on-chip active serial controller(?) and generally does
- // way more than we want.
- //
- // See the "Dedicated Remote System Upgrade Circuitry" section of the
- // Remote System Upgrade chapter (vol 1, chapter 8) of the Cyclone IV
- // manual.
- //
- // A refinement of this would be to allow shifting in a new boot address;
- // see the MAX 10 Configuration User Guide. for low-level protocol details
- // and the above reference for higher level protocol.
- //
- // At some point the Altera remote configuration IP is pretty much
- // what's needed anyway, though.
- //
- module fpgarst
- (
- input rst_n,
- input clk,
- input reconfig
- );
- // The internal primitive connecting to hard logic;
- // ru stands for "remote update block"
- cycloneive_rublock ru
- (
- .clk ( clk ), // Is this even needed?
- .rconfig ( reconfig ), // Start reconfiguration
- .rsttimer ( 1'b0 ), // Don't reset the timer
- .regin ( 1'bx ), // Shift register data in
- .regout ( ), // Shift register data out
- .captnupdt ( 1'b0 ), // Capture/update#
- .shiftnld ( 1'b0 ) // Shift/load# shift register
- );
- endmodule // fpgarst
|